Describing Your Robot Platform in a Research Paper: What Reviewers Expect in the Methods Section
Tom Cosgrove,

TL;DR: When you describe your robot platform in a robotics research paper, reviewers are not looking for marketing language. They are looking for enough detail to reproduce your setup. That means the exact platform model and hardware revision, every sensor with mounting position and acquisition rate, software stack with pinned versions (ROS 2 distribution, driver commits, firmware), calibration procedure and residuals, and test conditions including terrain, lighting, temperature, and payload. If a competent reader cannot rebuild your experiment from the Methods section alone, the section is incomplete. This guide gives you a section-by-section structure and a reviewer checklist you can run before submission.
Why does describing your robot platform in a robotics research paper decide reproducibility?
Reproducibility in mobile robotics fails for mundane reasons. A paper reports a SLAM accuracy improvement but never states the IMU sample rate. Another compares path-following controllers without naming the wheel diameter or whether tires were pneumatic or solid. A third reports autonomous navigation success rates on “outdoor terrain” with no description of the surface.
None of those omissions are malicious. They happen because the author knows their own system so well that the parameters feel obvious. They are not obvious to a reviewer, and they are certainly not obvious to a team three years later trying to build on the work.
Describing your robot platform in a research paper is therefore a technical writing task with a concrete acceptance criterion: a reader with comparable hardware and a reasonable budget should be able to reconstruct the experiment. Everything else in this guide follows from that criterion.
There is a secondary reason that matters more each year. Reviewers increasingly check whether the described configuration is internally consistent. If you claim a 30 Hz control loop over a link that cannot sustain it, or report localization drift below the resolution of your ground truth method without accounting for reference uncertainty, the inconsistency becomes an objection. Precise hardware description protects you from that.
What platform details belong in the hardware subsection?
Start with identity. The platform name alone is not enough, because open-source and commercial mobile robots evolve. Fictionlab’s Leo Rover, for example, has gone through multiple hardware generations with different control electronics and onboard computers. Stating “Leo Rover” without a version leaves a reviewer unable to determine which motor controller firmware or which Raspberry Pi model you used.
A complete hardware identity block includes the following items, each of which a reader needs to match your configuration:
- Manufacturer and model, written as it appears in official documentation, not as an internal lab nickname.
- Hardware version or generation, plus any revision markings on the main control board.
- Drive configuration: number of driven wheels, drive type (differential, skid-steer, Ackermann), gear ratio, and encoder type and resolution.
- Dimensions and mass as tested, including payload. The catalog mass of a bare platform is rarely the mass you ran experiments with.
- Wheel and tire specification: diameter, width, material, and inflation pressure if pneumatic. This single parameter drives odometry error and traction behavior more than most authors acknowledge.
- Power system: battery chemistry, nominal voltage, capacity, and whether experiments ran on battery or tethered supply.
- Onboard computer: exact model, RAM, storage medium, and cooling arrangement if thermal throttling could affect your results.
Pull these numbers from official specifications or your own measurements. Do not estimate from memory. If you modified the platform – a different wheel set, an added mast, a replaced computer – say so explicitly and state what the stock configuration was. Modifications are perfectly acceptable in research. Undocumented modifications are not.
How much detail is too much?
A useful test: include a parameter if changing it would plausibly change your results by more than your reported measurement uncertainty. Wheel diameter affects odometry, so include it. The color of the chassis does not, so leave it out. When in doubt, move marginal detail to supplementary material or a public repository and reference it from the Methods section.
How should you document sensors and their mounting?
Sensor description is where most Methods sections thin out. A line reading “we used a 2D lidar and a depth camera” tells a reviewer almost nothing. Two systems with that description can differ by an order of magnitude in range, update rate, and noise characteristics.
For each sensor on the platform, report the following, because each item changes how the data can be interpreted:
- Manufacturer, model, and firmware version. Firmware matters; vendors change filtering behavior between releases.
- Configured operating mode. Many sensors support multiple resolutions, ranges, or scan patterns. State the one you used, not the full capability list.
- Acquisition rate as configured and as actually achieved. These differ. If a camera is set to 30 fps but the USB bus delivers 22 fps under load, report the measured rate.
- Mounting position and orientation relative to the robot base frame, with the frame convention stated (for example, REP 103 right-handed coordinates: X forward, Y left, Z up).
- Field of view and occlusions. A lidar partly blocked by a mast or antenna produces a characteristic data gap. Say where it is.
- Synchronization method. Hardware trigger, software timestamp, PTP, or none. State it, because sensor fusion results depend on it heavily.
Mounting geometry deserves a figure or a transform table. A labeled photograph of the platform with sensor positions annotated, plus the numerical transforms, answers more reviewer questions than three paragraphs of prose. If your project publishes a URDF, reference the file and the commit hash.
What does a reviewer expect in the software and ROS 2 section?
Software description in robotics papers has a specific failure mode: naming packages without versions. “We used Nav2 and slam_toolbox” is not reproducible, because both change substantially between releases.
A software subsection that holds up under review states these items explicitly:
- Operating system and kernel version, including whether a real-time patch was applied.
- ROS 2 distribution by name (for example, Humble, Jazzy, Kilted, or Rolling) and the specific patch release if you tracked it.
- DDS implementation and configuration. Fast DDS, Cyclone DDS, and others behave differently under load. QoS profiles for critical topics belong here too.
- Every significant package with version or commit hash. For packages you modified or wrote, give a repository URL and a permanent identifier.
- Microcontroller firmware version for the motor controller or sensor board, since low-level control loops often live there.
- Parameter files. Navigation stacks have hundreds of tunable parameters. Publish the YAML files rather than listing values in prose.
- Containerization details, if you used Docker or similar, including base image and tag.
The most practical approach is to publish a repository containing launch files, parameter files, and a dependency lockfile, then cite it with a DOI from Zenodo or an equivalent archive. The paper then carries a summary table, and the repository carries the exact state. Reviewers respond well to this because it lets them verify claims without expanding the manuscript.
One caution on ROS 2 specifically: state whether you ran the default or a tuned executor, and whether nodes were composed into a single process. On resource-constrained onboard computers, composition can change latency enough to affect control performance. That detail is cheap to write and expensive to omit.
How do you report calibration so results can be trusted?
Calibration is the link between raw sensor output and the metric claims in your results. If calibration is undocumented, every number downstream becomes an estimate of unknown quality.
Report calibration as a procedure plus an outcome. The procedure covers what you did; the outcome covers how well it worked.
Intrinsic calibration
For cameras, state the model used (pinhole with radial-tangential distortion, fisheye, or other), the tool and version, the target type and dimensions, the number of images, and the reported reprojection error in pixels. For IMUs, state whether you performed a static bias and noise characterization, which method, and over what duration. Give the resulting noise density and random walk values you fed into your estimator.
Extrinsic calibration
Sensor-to-sensor and sensor-to-base transforms need a stated source. There is a meaningful difference between transforms measured from CAD, measured with calipers, and estimated with a calibration routine. All three are defensible. Which one you used changes the uncertainty a reader should assume. Report the residual error where the method produces one.
Odometry and kinematic calibration
For wheeled platforms, document wheel radius and track width as calibrated, not as specified. Manufacturing tolerance, tire wear, and load deflection all shift effective radius. If you ran a calibration procedure such as a straight-line and rotation test, describe the distance, the number of trials, and the correction factors obtained. If you did not calibrate, state that you used nominal values, which is an honest and acceptable choice when odometry is not the subject of the claim.
Calibration stability
State when calibration was performed relative to the experiments, and whether it was re-run between sessions. Field robotics is hard on mounts. A calibration from before a week of vibration-heavy outdoor runs is a different calibration.
What test conditions must be described for field experiments?
Indoor benchmark datasets have implicit conditions. Field experiments do not. When you take a platform like the Leo Rover or Raph Rover into outdoor research scenarios, the environment becomes an experimental variable, and reviewers will ask you to characterize it.
Describe the test environment with enough specificity that a reader can find or recreate something equivalent:
- Surface type and condition: asphalt, compacted gravel, loose sand, grass height, mud depth, snow. Add slope range if relevant.
- Geographic location and date range. Coordinates at reasonable precision help enormously for outdoor work, and support later comparison.
- Weather and illumination: temperature range, precipitation, cloud cover, time of day. Vision-based methods are sensitive to all of these.
- GNSS conditions, if used: receiver model, correction method (RTK, PPP, none), satellite count, and typical reported accuracy during runs.
- Ground truth method and its uncertainty or accuracy. Motion capture, RTK GNSS, total station, or surveyed markers each have different error floors. Claims of accuracy below the reference uncertainty require an uncertainty analysis beyond the reference measurement alone.
- Trial structure: number of runs, distance or duration per run, randomization or ordering, and how failed runs were handled.
- Payload and configuration during tests, since mass distribution affects traction and odometry.
Be explicit about excluded data. If three runs out of twenty were discarded due to a hardware fault, say so and say why. Reviewers treat disclosed exclusions as a sign of care and undisclosed ones as a reason to doubt the rest.
How do you make the work replicable beyond the paper?
Replicability is a function of what you publish alongside the text. A well-written Methods section describes the setup; an archived artifact set lets someone rebuild it.
Useful artifacts to publish, roughly in order of how much they help a reader, include:
- Configuration and launch files for the full stack as run, archived with a DOI.
- Calibration files, including camera intrinsics, extrinsic transforms, and IMU noise parameters.
- URDF or robot description matching the tested hardware, including sensor mounts.
- Raw or lightly processed datasets such as ROS 2 bag files, with a topic list and recording conditions documented.
- Evaluation scripts that transform raw logs into the figures and tables in the paper.
- A bill of materials for custom brackets, mounts, or electronics, plus CAD or fabrication files where applicable.
Open hardware platforms have an advantage here, because the base platform documentation may already exist publicly and you only need to document your additions and the exact baseline configuration. This can reduce the reproducibility burden on the author.
What should you check before you submit?
Run this checklist against your draft. Each item corresponds to a question reviewers commonly raise about robot platform descriptions.
- Is the platform named with manufacturer, model, and hardware version?
- Is the as-tested mass stated, including payload?
- Are wheel or track specifications given, with tire pressure if applicable?
- Is every sensor listed with model, firmware, configured mode, and achieved rate?
- Are sensor mounting positions given numerically, with the frame convention stated?
- Is time synchronization between sensors described?
- Is the ROS 2 distribution named, along with DDS implementation and relevant QoS settings?
- Does every custom or modified package have a repository link and commit hash?
- Are parameter files published rather than paraphrased?
- Is microcontroller or motor driver firmware version reported?
- Is each calibration described with method, tool, and residual error where applicable?
- Is it clear when calibration was performed relative to the experiments?
- Is the test surface characterized beyond a one-word label?
- Are weather, lighting, and temperature ranges reported for outdoor work?
- Is the ground truth method named with its stated uncertainty or accuracy?
- Is the number of trials given, with any exclusions disclosed and explained?
- Could a reader with the same hardware reach the same configuration from what you wrote?
If more than two items fail, the Methods section needs another pass before review, not after.
Frequently asked questions
How long should the platform description be in a robotics paper?
There is no fixed length. A thorough hardware and software description should use enough space to state the parameters needed to interpret and reproduce the experiment, supported where useful by a figure and tables. Additional implementation detail can go in supplementary material. The target is completeness per parameter, not word count.
Should I describe a commercial platform if its datasheet is public?
Yes, but selectively. Cite the official documentation for the full specification, then reproduce in the paper only the parameters that affect your results: drive configuration, wheel geometry, mass as tested, compute, and power. Readers should not have to open a datasheet to understand your experiment, and datasheets can move or change.
What if I used default parameters and never tuned anything?
State that explicitly, name the package version, and note that defaults were used. This is a legitimate and informative choice. Problems arise only when readers cannot tell whether values were defaults or tuned, because that ambiguity makes comparison impossible.
How do I report accuracy when ground truth is imperfect?
Report your ground truth method and its uncertainty or accuracy first, then your measurements. If your reference has approximately 2 cm accuracy, a sub-centimeter localization-error claim cannot be supported by that reference alone without a suitable uncertainty analysis. Where the error you measure approaches the reference error, say so directly and frame the result as bounded by the reference.
Do I need to publish ROS 2 bag files?
Not always, but it strengthens the paper considerably when datasets are central to the contribution. If full bags are impractical due to size, publish a representative subset with a documented topic list and recording conditions, and provide the evaluation scripts so readers can verify the processing pipeline.
How do I handle modifications to an open-source platform?
Describe the stock configuration and exact hardware revision, then describe each modification and its purpose. Publish CAD files or a bill of materials for custom parts and an updated URDF. Public documentation for the base platform can reduce the amount of repeated detail, but it does not replace identifying the tested baseline configuration.
Is a photo of the robot sufficient instead of a diagram?
A photo helps readers recognize the system, but it does not convey transforms. Use both where space allows: a photo for context and an annotated diagram or transform table for geometry. If you must choose one, choose the one carrying numerical mounting information.
Where to go from here
Precise platform description is a habit, not a one-time task. Build the hardware table, the software version list, and the calibration record while you run the experiments, not in the week before submission. The parameters are easy to capture in the moment and difficult to reconstruct afterward.
To see how other research teams have described open-source mobile robots in their Methods sections, including sensor configurations, ROS 2 stacks, and field test conditions, browse the collection of published papers using Leo Rover and Raph Rover platforms.